MTP-24 to 3 x MTP-8 APC Breakout Cable, 24 Fibers, OS2, Type B

Factory built MTP® Elite Female breakout assembly with 24 Fibers on OS2 9/125μm fiber. The main trunk stays one cable until the fan-out point, which keeps pathways clear and makes moves and changes much easier to trace.
Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.
Product Highlights
- MTP® Elite Female (Non-Pinned) to MTP® Elite Female (Non-Pinned), 24 Fibers
- OS2 9/125μm, G.657.A1
- Insertion loss ≤0.35dB (0.15dB Typ.), return loss ≥60dB
- Type B polarity
- 3.0mm Plenum (OFNP) round cable
- Minimum bend radius 10mm
- Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order
Specifications
| Part Number | 24FMTPSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP® Elite Female (Non-Pinned) |
| Connector B | US Conec MTP® Elite Female (Non-Pinned) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC to APC |
| Polarity | Type B |
| Cable Jacket | Plenum (OFNP) |
| Fiber Count | 24 Fibers |
| Glass Fiber | G.657.A1 |
| Minimum Bend Radius | 10mm |
| Cable Outside Diameter (OD) | 3.0mm |
| Breakout Length | 0.5m |
| Installation Tensile Load | 66N |
| Tensile Strength | 80/240N (Long/Short Term) |
| Insertion Loss | ≤0.35dB (0.15dB Typ.) |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
Applications
In leaf-spine and GPU cluster cabling, this breakout replaces a cassette plus multiple jumpers with one tested assembly. A 24-fiber MPO interface is the standard for 100GBASE-SR10 CFP, CFP2 and CPAK modules, and is equally at home in structured trunking between panels. Each leg is marked so port mapping is unambiguous during installation.
Breakout Geometry and Wiring
The fan-out point is factory molded and strain relieved, with each breakout leg built to the length shown in the specification table. Wiring follows the polarity scheme listed, so the lane order at the far end matches the transceiver requirements without on-site re-termination.
Ordering Information
Please reference 24FMTPSMF in your enquiry. The 1m (3ft) version is the standard model; Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.
Quality and Testing
We do not ship untested product. Each unit is measured on calibrated equipment for optical performance and visually inspected for end face quality before packing. Batch traceability is maintained so any field issue can be tracked back to production.
How We Pack
Each assembly is coiled, capped and sealed in an individual bag, then packed into foam lined export cartons. Test reports can be attached per unit or per batch, and carton marks follow your shipping instructions.
Logistics
We dispatch worldwide by international courier, with air and sea freight options for bulk orders. Goods can be sent collect on your courier account, and documentation for customs clearance is provided with every shipment.