Brocade 40G-QSFP-4SFP-C-0105 Compatible QSFP+ to 4SFP+ Passive Breakout Copper Cable, 0.5m (2ft)

The 40G-QSFP-4SFP-C-0105 compatible DAC cable provides 40G connectivity for Brocade equipment over a fixed 0.5m (2ft) assembly. Both ends use the stated QSFP+ to 4 SFP+ arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.
OEM Part Number: 40G-QSFP-4SFP-C-0105HT Part Number: 40G-QSFP-4SFP-C-0105
Product Highlights
- Compatible alternative to Brocade 40G-QSFP-4SFP-C-0105
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to 4 SFP+
- Fixed length and part number: 0.5m (2ft), 40G-QSFP-4SFP-C-0105
- Conductor specification: 30AWG
- Minimum bend radius: 21mm
Specifications
| HT Part Number | 40G-QSFP-4SFP-C-0105 |
|---|---|
| Brocade Compatible | 40G-QSFP-4SFP-C-0105 |
| Manufacturer | HT |
| Connector Type | QSFP+ to 4 SFP+ |
| Data Rate | 40Gbps |
| Minimum Bend Radius | 21mm |
| Wire AWG | 30AWG |
| Cable Length | 0.5m (1.64ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, SFF-8431 and QSFP+ MSA |
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Position Within the Length Range
40G-QSFP-4SFP-C-0105 is the shortest of 7 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is 40G-QSFP-4SFP-C-0101 at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431 and QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing 40G-QSFP-4SFP-C-0105; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Brocade Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original Brocade cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 40G-QSFP-4SFP-C-0105.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.