Brocade 40G-QSFP-C-0701 Compatible 40G QSFP+ Passive Copper Cable, 7m (23ft)

This 7m (23ft) DAC assembly is made for installations that call for Brocade 40G-QSFP-C-0701 at 40G. The QSFP+ to QSFP+ connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: 40G-QSFP-C-0701HT Part Number: 40G-QSFP-C-0701
Product Highlights
- Compatible alternative to Brocade 40G-QSFP-C-0701
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to QSFP+
- Fixed length and part number: 7m (23ft), 40G-QSFP-C-0701
- Conductor specification: 26AWG
- Minimum bend radius: 47.5mm
Specifications
| HT Part Number | 40G-QSFP-C-0701 |
|---|---|
| Brocade Compatible | 40G-QSFP-C-0701 |
| Manufacturer | HT |
| Connector Type | QSFP+ to QSFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 47.5mm |
| Wire AWG | 26AWG |
| Cable Length | 7m (22.97ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, QSFP+ MSA and IEEE 802.3ba |
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 47.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Position Within the Length Range
40G-QSFP-C-0701 is the longest of 7 verified length options in this family. Compared with 40G-QSFP-C-0501 at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 47.5mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, QSFP+ MSA and IEEE 802.3ba. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 7m (23ft) reach of 40G-QSFP-C-0701 is useful only when the managed pathway requires it; straight-line distance between ports is not a sufficient measurement. Check the route around rack rails, cable managers and maintenance clearances, then protect the complete copper assembly and both connector housings from tight bends and unsupported spans. The next shorter verified assembly is 40G-QSFP-C-0501 at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Brocade Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original Brocade cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 40G-QSFP-C-0701.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Keep 40G-QSFP-C-0701 associated with 7m (23ft) throughout the order and receiving record.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
