800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 IHS/Finned Top Passive Copper Breakout Cable, 1m (3ft)

For a direct equipment connection requiring Generic 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT, this page supplies the 1m (3ft) version with 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top). The cable supports 800G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT
Product Highlights
- HT-manufactured DAC assembly in 1m (3ft)
- 800G connectivity at 800Gbps
- Interface configuration: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)
- Fixed length and part number: 1m (3ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT
- Cable construction: Passive Breakout DAC
- Conductor specification: 28AWG
- Maximum power consumption: 0.1W (800G End)0.1W (400G Per End)
- Minimum bend radius: 40.5mm
Specifications
| HT Part Number | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top) |
| Max Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 40.5mm |
| Max. Power Consumption | 0.1W (800G End)0.1W (400G Per End) |
| Cable Length | 1m (3ft) |
| Wire AWG | 28AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PVC |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
| Modulation Format | 8x 100G PAM4 to Dual 4x 100G PAM4 |
Signal and Lane Configuration
The listed modulation format is 8x 100G PAM4 to Dual 4x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PVC.
Power and Thermal Planning
The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 1m (3ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1M3FT occupies the middle of this family between 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT at 0.5m (2ft) and 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.
Generic Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.