Dell ACC-Q56DD-400G-5M Compatible 400G QSFP-DD 8 x 50G PAM4 Active Copper Twinax Cable, 5m (16ft)

This 5m (16ft) ACC assembly is made for installations that call for Dell ACC-Q56DD-400G-5M at 400G. The QSFP-DD connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: ACC-Q56DD-400G-5MHT Part Number: ACC-Q56DD-400G-5M
Product Highlights
- Compatible alternative to Dell ACC-Q56DD-400G-5M
- 400G connectivity at 425Gbps
- Interface configuration: QSFP-DD
- Fixed length and part number: 5m (16ft), ACC-Q56DD-400G-5M
- Cable construction: Active Twinax
- Conductor specification: 28AWG
- Maximum power consumption: 2.5W Per End
- Minimum bend radius: 80mm
Specifications
| HT Part Number | ACC-Q56DD-400G-5M |
|---|---|
| Dell Compatile | ACC-Q56DD-400G-5M |
| Manufacturer | HT |
| Form Factor | QSFP-DD |
| Max. Data Rate | 425Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 80mm |
| Max. Power Consumption | 2.5W Per End |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8636 |
Power and Thermal Planning
The rated power consumption is 2.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
The 5m (16ft) length gives ACC-Q56DD-400G-5M more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
ACC-Q56DD-400G-5M is the longest of 2 verified length options in this family. Compared with ACC-Q56DD-400G-3M at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 80mm; the stated power consumption is 2.5W Per End; the jacket material is PVC.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 80mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Dell Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original Dell cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Dell ACC-Q56DD-400G-5M.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to ACC-Q56DD-400G-5M.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.