Tanzania Fiber Optics

fiber optic products manufacturing since 1995

Arista Networks C-D800-D800-0.5M Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

Arista Networks C-D800-D800-0.5M Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

For a direct equipment connection requiring Arista Networks C-D800-D800-0.5M, this page supplies the 0.5m (2ft) version with QSFP-DD to QSFP-DD. The cable supports 800G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.

OEM Part Number: C-D800-D800-0.5MHT Part Number: C-D800-D800-0.5M

Product Highlights

  • Compatible alternative to Arista Networks C-D800-D800-0.5M
  • 800G connectivity at 800Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 0.5m (2ft), C-D800-D800-0.5M
  • Cable construction: Passive DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.005W Per End
  • Minimum bend radius: 69mm

Specifications

HT Part NumberC-D800-D800-0.5M
Arista Networks CompatibleC-D800-D800-0.5M
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive DAC
Cable Length0.5m (2ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius69mm
Wire AWG30AWG
Max. Power Consumption0.005W Per End
Modulation Format8x 100G-PAM4
Commercial TemperatureRange0 to 70°C (32 to 158°F)
Application800G Ethernet
ProtocolsQSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing C-D800-D800-0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

C-D800-D800-0.5M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is C-D800-D800-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 69mm; the stated power consumption is 0.005W Per End; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.005W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 69mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include QSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.

Arista Networks Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original Arista Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks C-D800-D800-0.5M.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

You are here: Home 100BASE SFP Arista Networks C-D800-D800-0.5M Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support