4F CS UPC to LC UPC Duplex Push-Pull Tab Uniboot OS2 Fiber Patch Cable

4F CS UPC to LC UPC Duplex Push-Pull Tab Uniboot OS2 Fiber Patch Cable

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This OS2 fiber patch cable carries a CS UPC interface on one end and a LC UPC interface on the other, factory terminated on OS2 glass and optically tested as a complete unit. The uniboot build places both fibers of the duplex connection inside a single round 2.0mm cord with one combined connector housing, halving the supplied cable count in density-optimized panels and simplifying polarity management.

Product Highlights

  • Uniboot Allows One Cable to Carry Two Fibers to Reduce the Cable Bulk When Routing
  • G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
  • Patch 2x CS™ with Gang-Clip Simultaneously to QSFP-DD
  • Push-Pull Tab for Installation and Removal with One Hand Without Needing Additional Tools
  • Flat Clip Design Provides Additional Space Between Connectors and Improves Airflow

Specifications

Fiber Count4 Fibers (Base-2)
Fiber GradeG.657.A1 (Compatible with G.652.D)
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Flame RatingRiser (OFNR)
Tensile Strength33/100N (Long/Short Term)
PolarityA (Tx) to B (Rx)
Cable Outside Diameter (OD)2.0mm
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Insertion Loss≤0.2dB
Return Loss≥50dB
Attenuation at 1310nm≤0.4dB/km
Attenuation at 1550nm≤0.3dB/km
Operating Temperature-10 to 70°C (14 to 158℉)
Storage Temperature-20 to 70℃ (-4 to 158℉)

Connector and polish choices in the single-mode plant

The OS2 interface on this jumper follows the polish discipline of the network it serves. Because mixing polishes on a mated pair destroys the return loss and can damage the ferrules, the patch side should be matched to the rack-mounted panel side exactly. When the documentation is unclear, the boot color and the connector being used housing tell the truth: green for APC, blue or beige for UPC.

Bend tolerance in real cabinets

Patch fields are rarely kind to fiber. Patch cords path through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in this optical assembly tolerates a 10mm fiber bend radius; thus, a hurried routing decision during a night servicing window does not automatically turn into a measurable penalty on the connection.

Polarity without re-terminating

Uniboot connectors expose the polarity through the housing rather than the termination: the latches or clips let the installer swap the fiber positions without opening the cord. A polarity mistake discovered at turn-up becomes a two-minute correction instead of a replacement order. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.

Length Options

Standard offerings cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), with customized length supplied beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the installed connectors.

Quality Control and Testing

Every supplied assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The supplied cable ships with dust caps on both connectors and the test result supplied on order.

Ordering and Factory Support

Refer to this setup by connector pair, fiber mode and length when purchasing a quotation. For configurations outside the listed options, mixed connector families, jackets, labeling or project packaging, send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP 4F CS UPC to LC UPC Duplex Push-Pull Tab Uniboot OS2 Fiber Patch Cable

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support