Tanzania Fiber Optics

fiber optic products manufacturing since 1995

Customized OM2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated

Customized OM2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This customized multi-fiber cable is a pre-terminated indoor/outdoor rated unit built exactly to the setup the project specifies: connector styles and polish at each end, fiber count, jacket rating, breakout geometry and length are all specified at order time, and the finished trunk is optically tested leg by leg before dispatch. Because the indoor/outdoor build carries a flame-rated jacket that further tolerates moisture and ultraviolet exposure, one unit can run from an outdoor entry point directly into the building without a transition splice at the wall.

Product Highlights

  • Custom Cable with Pre-terminated Connectors, Breakout Types and Pulling Eye
  • Optical Performance Test for Normal Network Connections
  • Meet the IEC 60794-1 and IEC 60794-2-20 Standard
  • Feature a UV Stabilized and Moisture Resistant Outer Jacket
  • Available from 4 Fibers with Variable Length

Specifications

Connector TypeLC/SC/ST/FC/Unterminated
Polish TypeUPC
Fiber ModeOM2 50/125μm
Fiber Count4 Fibers
Minimum Bend Radius20/10D (Dynamic/Static)
Breakout Outside Diameter (OD)2.0mm
Trunk Outside Diameter (OD)5.0mm
Insertion Loss≤0.3dB
Return Loss≥30dB
Cable TypeTight Buffered
Fiber GradeBend Insensitive
Operating Temperature-20 to 60°C (-4 to 140°F)

Matching the installed base

When a legacy trunk fails, the correct repair is a cable that matches the installed fiber grade. Because mixing OM1 with OM3 introduces a core-size transition that adds unpredictable loss, building the replacement trunk on the original grade is cheaper than fault finding a mismatched one.

Legacy multimode for installed systems

OM1 and OM2 cabling remains in service in industrial controls, building automation and older campus networks. This optical assembly matches that plant: the 62.5/125 or 50/125 core mates correctly with the existing infrastructure, avoiding the modal mismatch that mixing core sizes would create.

Pulling eye and installation practice

A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps the installed trunk from twisting, which matters on long riser runs and congested trays. The installation load rating on the datasheet is the number the pulling rope should respect, not the weight of the reel.

Breakout geometry and why it matters

The breakout is where a trunk becomes usable. Equal-length legs suit a straight row of adjacent ports, whereas staggered legs reach a column of ports without slack piling up at one end. The 2.0mm legs survive patching-field handling; the 0.9mm version suits protected routing inside panels and cassettes. Selecting the geometry at order time means the supplied assembly arrives matching the hardware it serves.

Planning a trunk route

A multi-fiber trunk is planned once and installed once; thus, the planning deserves the hour it takes. Measure the path through the actual containment, note the bend space at both connector ends, and decide which end gets pulled. State the pulling eye specification with the order if the path is long or congested. At the far end, leave the dressing slack the rack-mounted panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before fabrication.

Pre-terminated versus field termination

Terminating OM2 fiber in the field means a splicer, a tray location, consumables and the craft time to do it well - multiplied by every fiber in the installed trunk. A pre-terminated unit moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives the supplied cable routes it, dresses the legs and mates the installed connectors; the connection is ready for light the identical hour. Since every field-terminated leg is another chance for a rework visit, for multi-fiber counts the saving cannot be regarded as linear but compounding,.

Fiber Count Choices

Fiber count is specified at order time: 4 Fibers, 8 Fibers are standard options for this build. Selecting the count is a capacity decision - plan the active links, add the spares the servicing practice calls for, and the installed trunk arrives with every leg terminated and tested.

Custom Lengths as Standard Practice

Standard offerings cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), 25m (82ft), with customized length supplied beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured path length keeps the slack out of the tray and the strain off the installed connectors.

Factory Quality Control and Testing

Every trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on each fiber, and end-face geometry is inspected for consistent physical contact. The supplied assembly ships with dust caps on every connector used and the test results supplied on order.

Purchase and Factory Support

Refer to this setup by fiber mode, fiber count, connector pair, breakout geometry and length when purchasing a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, labeling or project packaging - send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP Customized OM2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support