Tanzania Fiber Optics

fiber optic products manufacturing since 1995

Customized OS2 Indoor Multi-Fiber Bunch Cable, LC/SC/FC/ST/LSH, 0.9/2.0mm Breakout

Customized OS2 Indoor Multi-Fiber Bunch Cable, LC/SC/FC/ST/LSH, 0.9/2.0mm Breakout

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This customized multi-fiber cable is a pre-terminated indoor unit built exactly to the setup the project specifies: connector styles and polish at each end, fiber count, jacket rating, breakout geometry and length are all specified at order time, and the finished trunk is optically tested leg by leg before dispatch. The bunch build arranges the 0.9mm tight-buffered fibers around a central strength member inside a round trunk, giving a flexible, pulling-friendly cable for congested indoor pathways.

Product Highlights

  • Available in Riser (OFNR)/LSZH/Plenum (OFNP) Flame-Retardant Trunk Jacket
  • Available in LC/SC/FC/ST/LSH Connector Type
  • Available in 0.9/2.0mm Breakout Diameter
  • G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
  • Precision Zirconia Ferrule Connectors Ensure Low Loss

Specifications

Connector TypeLC/SC/ST/FC/LSH
Polish TypeUPC/APC
Fiber Count2 Fibers
Fiber GradeG.657.A1 (Compatible with G.652.D)
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Flame Rating (Trunk)Riser (OFNR)/LSZH/Plenum (OFNP)
Breakout Length
Trunk Outside Diameter (OD)3.0±0.1mm
Breakout Outside Diameter (OD)0.9/2.0mm
PolarityA (Tx) to B (Rx)
Cable TypeTight-Buffered
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength50/100N (Long/Short Term)
Insertion Loss≤0.3dB
Return LossUPC≥50dB, APC≥60dB (LC/SC/ST/FC)
Attenuation at 1310nm0.4dB/km
Attenuation at 1550nm0.3dB/km
Operating TemperaturePlenum (OFNP): 0 to 60°C (32 to 140°F)
Storage TemperaturePlenum (OFNP): -10 to 70°C (14 to 158°F)

Bend-insensitive glass in real pathways

Backbone routes turn through tight tray corners, congested risers and crowded vertical channels. Because the G.657.A1 bend-insensitive fiber in this optical assembly tolerates a 10mm fiber bend radius, a hurried routing decision during a night servicing window does not automatically turn into a measurable penalty on the connection. The glass remains fully compatible with the G.652.D plant it connects to.

Single-mode trunks for building and campus backbones

A pre-terminated OS2 trunk carries the links that leave the room: riser spans between floors, campus backbones between buildings and every wavelength-multiplexed service in between. Because the glass is the identical group used in the outside plant, the supplied assembly does not automatically become the weak point of the optical link budget. At 1310 and 1550nm the attenuation stays a fraction of a decibel per kilometer, and each factory-polished connector adds less than 0.3dB when the end faces are clean and seated.

Breakout geometry and why it matters

The breakout is where a trunk becomes usable. Equal-length legs suit a straight row of adjacent ports, whereas staggered legs reach a column of ports without slack piling up at one end. The 2.0mm legs survive patching-field handling; the 0.9mm version suits protected routing inside panels and cassettes. Selecting the geometry at order time means the supplied assembly arrives matching the hardware it serves.

Pulling eye and installation practice

A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps the installed trunk from twisting, which matters on long riser runs and congested trays. The installation load rating on the datasheet is the number the pulling rope should respect, not the weight of the reel.

Planning a trunk route

A multi-fiber trunk is planned once and installed once; thus, the planning deserves the hour it takes. Measure the path through the actual containment, note the bend space at both connector ends, and decide which end gets pulled. State the pulling eye specification with the order if the path is long or congested. At the far end, leave the dressing slack the rack-mounted panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before fabrication.

Pre-terminated versus field termination

Terminating OS2 fiber in the field means a splicer, a tray location, consumables and the craft time to do it well - multiplied by every fiber in the installed trunk. A pre-terminated unit moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives the supplied cable routes it, dresses the legs and mates the installed connectors; the connection is ready for light the identical hour. Since every field-terminated leg is another chance for a rework visit, for multi-fiber counts the saving cannot be regarded as linear but compounding,.

Fiber Count Choices

This build is built with 2 Fibers per trunk, terminated and tested as a complete unit.

Custom Lengths as Standard Practice

Standard offerings cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), 25m (82ft), with customized length supplied beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured path length keeps the slack out of the tray and the strain off the installed connectors.

Factory Quality Control and Testing

Every trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on each fiber, and end-face geometry is inspected for consistent physical contact. The supplied assembly ships with dust caps on every connector used and the test results supplied on order.

Purchase and Factory Support

Refer to this setup by fiber mode, fiber count, connector pair, breakout geometry and length when purchasing a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, labeling or project packaging - send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP Customized OS2 Indoor Multi-Fiber Bunch Cable, LC/SC/FC/ST/LSH, 0.9/2.0mm Breakout

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support