Customized Simplex OM1/OM2 LC/SC/FC/ST/LSH Fiber Optic Pigtail

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This customized pigtail platform is built to the ordered setup: OM1/OM2 fiber mode, connector series, polish, jacket rating and length are all confirmed before fabrication. Because every leg is factory terminated, polished and optically tested, the splice point inherits a connector end face that field polishing cannot match.
Product Highlights
- Available in LC, SC, FC, ST, LSH Connectors
- Optical Testing Guarantees Insertion Loss and Returns Loss
- Pass All IEC-61754 and TIA-605 (FOCIS) Performance Requirements
- Easy-strip Tight-buffered Coating
- Available in PVC (Unrated)/Riser (OFNR)/LSZH/Plenum (OFNP) Cable Jacket
Specifications
| Connector A | LC/SC/FC/ST/LSH UPC Simplex |
|---|---|
| Connector B | Unterminated |
| Fiber Count | 1 Fiber |
| Fiber Grade | G.651 (OM1)/Bend Insensitive (OM2) |
| Fiber Mode | OM1 62.5/125μm, OM2 50/125μm |
| Wavelength | 850/1300nm |
| Jacket Color | Orange |
| Cable Jacket | 0.9mm: PVC (Unrated)/LSZH |
| Min. Bend Radius (Optical Fiber) | 15/7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 Times |
| Attenuation at 850nm | 3.0dB/km |
| Attenuation at 1300nm | 1.0dB/km |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥20dB |
| Operating Temperature | Plenum (OFNP): -10 to 60°C (14 to 140°F) |
| Storage Temperature | Plenum (OFNP): -10 to 70°C (14 to 158°F) |
| Wavelength(1) | Cable Jacket(1) |
| Operating Temperature(1) | Meter for Entire Strip(1) |
| Fiber Count(1) | Label(1) |
Why pigtails remain the standard termination
A pigtail is half an interface: one end is a factory-assembled connector, polished and tested under procedure control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the installed cable brings the connector being used quality of the factory to a field path. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the path length is uncertain or the pathway is difficult to pre-measure.
Fusion splicing practice that protects the budget
A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.
Ordering a customized pigtail platform
The customized platform turns a catalog of options into one ordered setup: connector series from LC, SC, FC, ST and LSH; polish as UPC or APC; jacket rating to suit the path; length to the measured run; and fiber count where the platform offers it. State the combination with the request and the factory confirms the manufacturable specification before fabrication. The delivered pigtail then matches the rack-mounted panel hardware, the tray geometry and the path without field improvisation.
Configuration choices that matter at the tray
Three choices decide how a customized pigtail behaves at the splice point: the connector being used series should be matched to the rack-mounted panel adapters, the polish discipline should be matched to the plant - mixing UPC and APC at one mating point destroys return loss - and the jacket rating must satisfy the pathway code. Getting these right at order time is faster than any field correction, and the factory test report then applies to the precise delivered setup.
Choosing the fiber mode for the plant
Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve equipment rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and should be matched like-for-like. The pigtail mode must equal the supplied cable plant mode - a mismatch splices poorly and performs worse.
Bend-insensitive glass in dense trays
Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning.
A splicing workflow that scales
Productive termination crews work to a fixed routine: mount the tray, dress the supplied cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency further makes quality auditable - identical materials, identical sequence, identical pass criteria across every site.
Sparing and kit planning for termination work
Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may generally be ordered to the identical specification.
Selecting the right pigtail for the job
Five decisions define the order: the connector being used series should be matched to the rack-mounted panel, the polish should be matched to the plant, the fiber mode should be matched to the supplied cable, the build should be matched to the path, and the count should be matched to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the specification sits outside the standard configurations, the customized platforms cover the remaining combinations.
Factory Quality Control and Testing
Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results supplied on order.
Purchase and Factory Support
Refer to this pigtail by connector, polish, fiber mode, fiber count and build when purchasing a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the specification with the request and the factory will ensure the manufacturable specification. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.