Customized Ultra Low Loss Duplex Fiber Patch Cable, LC/SC/FC/ST, OM4

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This customized fiber patch cable is built to the precise setup the project specifies: connector styles, polish, fiber mode, jacket and length are all specified at order time and the supplied assembly is factory terminated and optically tested before dispatch.
Product Highlights
- Bend Insensitive Fiber with 7.5mm Min. Bend Radius
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Duplex Zipcord Construction Reduces Risk of Damage from Crimping
- Available in LC, SC, FC, and ST ULL Connectors with 0.08dB Typ. IL
- Available in Riser (OFNR), LSZH, and Plenum (OFNP) Cable Jackets
Specifications
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM4 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR)/LSZH/Plenum (OFNP) |
| Cable Outside Diameter (OD) | 1.2/2.0/3.0mm |
| Polarity | A (Tx) to B (Rx) |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength (Long/Short Term) | 40/80N (1.2mm), 90/150N (2.0mm), 120/225N (3.0mm) |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | Plenum (OFNP): -10 to 60°C (14 to 140°F) |
| Storage Temperature | Plenum (OFNP): -10 to 70°C (14 to 158°F) |
Built to the order
The customized program covers the combinations that stock lists cannot: mixed connector families, non-standard jackets, unusual lengths, labeling and packaging to the project specification. The supplied assembly is terminated and tested exactly like a stock product, with the setup confirmed before fabrication.
Polarity and pairing in duplex links
A duplex jumper is two fibers with a defined A-to-B crossover. Getting polarity right at the cord level keeps the link consistent end to end, which is why these assemblies are built and tested as a pair rather than as two independent strands.
Multimode reach for the data hall
This OM4 unit serves the short-reach fabric of the data center: 10G and 25G server uplinks, 40G and 100G SR4 spine links and the inter-row runs between them. On OM4 glass, 10G Ethernet holds to 400 meters and 100G SR4 to 100 meters, which covers the overwhelming majority of in-hall routes with margin to spare.
Length Options
Standard offerings cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), with customized length supplied beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the installed connectors.
Quality Control and Testing
Every supplied assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The supplied cable ships with dust caps on both connectors and the test result supplied on order.
Ordering and Factory Support
Refer to this setup by connector pair, fiber mode and length when purchasing a quotation. For configurations outside the listed options, mixed connector families, jackets, labeling or project packaging, send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.