Hardened SC APC to SC APC Fiber Drop Cable, OS2, IP68, Custom Length

Hardened SC APC to SC APC Fiber Drop Cable, OS2, IP68, Custom Length

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. Whereas a standard SC APC connector plugs into the optical network terminal or indoor hardware on the subscriber side, this fiber drop cable connects the sealed outdoor terminal to the subscriber premises with one purpose-built interface at each end: a hardened SC APC connector, IP68 rated and environmentally sealed, mates directly with the terminal port on the distribution side. The supplied cable is the flat 2.0x5.0mm LSZH drop build with one G.657.A2 bend-insensitive OS2 fiber, factory terminated and manufactured to the ordered length.

Product Highlights

  • Sealed connector mates directly with outdoor terminal ports
  • G.657.A2 bend-insensitive fiber, 7.5mm minimum bend radius
  • Insertion loss ≤0.3dB, return loss ≥60dB
  • No splicing at the terminal, tool-less sealed mating
  • Manufactured to the ordered route length
  • Hardened SC APC (IP68) to standard SC APC

Specifications

Connector AHardened SC APC (IP68)
Connector BSC APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count1 Fiber
Fiber GradeG.657.A2
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)60/40mm (Dynamic/Static)
Trunk Outside Diameter (OD)2.0x5.0mm
Breakout Outside Diameter (OD)2.0x3.0mm
Breakout Length300±50mm
Cable JacketLow Smoke Zero Halogen (LSZH)
Tensile Load400N (Short Term)
Crush Resistance500N/100mm (Short Term)
Insertion Loss≤0.3dB
Return Loss≥60dB
Attenuation at 1310nm≤0.4dB/km
Attenuation at 1550nm≤0.3dB/km
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-10 to 50°C (14 to 122°F)

A sealed interface for the outdoor terminal

The distribution end of a drop path lives outdoors: in a terminal on a pole, a facade box or a handhole, exposed to rain, dust and condensation for years. The hardened SC APC connector is built for exactly that mating point. Its sealed housing threads directly onto the matching terminal port and closes to IP68; thus, the optical interface is protected against water and dust ingress without an enclosure around the interface itself. The connector being used accepts a standard SC APC interface inside, keeping full compatibility with the access network design.

Plug-and-play instead of splice-and-seal

The traditional alternative to a hardened drop is a field-spliced pigtail inside the terminal: a fusion splice, a splice tray location, heat-shrink protection and the craft time to do it well on a ladder. The hardened drop removes all of that. The installer routes the supplied cable, threads the connector being used onto the terminal port, and the connection is complete. Rollout crews connect more homes per day, and the skill specification at the drop point falls from splicing technician to installer, which is precisely where large FTTH programs save their cost.

One fiber, two very different ends

The two ends of this installed cable serve distinct worlds. Outdoors, the hardened connector faces weather, handling and repeated mating as subscribers are added and moved. Indoors, the standard SC APC end plugs into the optical network terminal on the subscriber wall. The 300mm breakout between the flat trunk and the 2.0x3.0mm tails gives both connector ends sufficient free fiber to dress into their enclosures without strain, and the G.657.A2 glass tolerates the tight corners of the indoor path.

Planning the orientation

The hardened end always faces the terminal, the standard end faces the subscriber, and the orientation is fixed at the factory. At quotation stage, state the path length jointly with the terminal type so the breakout and connector boot match the hardware. For routes where both connector ends terminate at sealed outdoor ports, the hardened-to-hardened model of this series extends the identical sealed interface to both connectors.

Custom lengths as standard practice

Since last-mile routes differ from a few meters to well over a hundred, every drop cable in this series is manufactured to the length stated with the order rather than picked from fixed stock sizes,. The supplied cable is manufactured to the length stated with the order; measure the path from the terminal port to the optical network terminal, including the vertical drop and entry route, and allow working slack at both connector ends. Specifying the measured path length avoids both the slack storage problem of an overlong cable and the strain risk of one that is too short.

Factory quality control and testing

Each unit is terminated with precision zirconia ferrule connectors and optically tested as a complete cable: insertion loss is verified against the 0.3dB ceiling and return loss against the 60dB minimum. Because the hardened connector is checked for seal integrity as well as optical operation, the delivered drop may generally be threaded onto the terminal port and put into service without on-site rework.

Purchase and Factory Support

Refer to the hardened to standard SC APC drop cable series when purchasing a quotation and state the path length, terminal type and number of units per length. For other hardened connector styles or both-end sealed builds, send the site specification with the request and the factory will ensure the manufacturable specification before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP Hardened SC APC to SC APC Fiber Drop Cable, OS2, IP68, Custom Length

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support