LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This duplex armored patch cable pairs two LC UPC connectors on an OS2 9/125µm single-mode unit protected by a helical stainless steel tube. The 3.0mm riser-rated (OFCR) jacket keeps the supplied cable flexible sufficient for cabinet and under-floor routing while the steel armor absorbs crushing, pulling and rodent damage that would interrupt an ordinary patch cord. G.657.A1 bend-insensitive glass keeps attenuation stable even where the pathway turns tightly around trays and rack posts.

Product Highlights

  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D dynamic/static bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥50dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • LC UPC to LC UPC duplex, OS2 9/125µm single mode

Specifications

Connector TypeLC to LC
Polish TypeUPC to UPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

Why steel armor instead of a conduit

Conventional patch patch cords depend on the surrounding duct or tray for mechanical protection. Where cables cross open floors, shared ceilings or industrial spaces, that protection cannot be regarded as always supplied. The helical steel tube inside this optical assembly wraps the buffered fibers directly; thus, the supplied cable itself carries the crush and rodent resistance. Technicians can path it through areas that would otherwise require metal conduit, which reduces both material cost and installation time while keeping the pathway smaller and easier to reconfigure later.

OS2 single-mode performance in duplex links

OS2 glass at 1310/1550nm supports the long-reach single-mode optics used in campus backbones, carrier access networks and data center interconnects. Because the duplex LC interface is the standard interface for SFP, SFP+, SFP28, QSFP+ and QSFP28 transceivers, one cable series covers links from 1G through 100G and beyond. G.657.A1 bend tolerance is fully compatible with legacy G.652.D plant, which means the supplied cable may generally be mixed into existing single-mode infrastructure without changing loss budgets.

Understanding the OFCR riser rating

OFCR stands for optical fiber conductive riser: a riser-rated cable whose metallic armor makes it conductive under building codes. The riser rating permits vertical runs between floors in shafts and riser closets. Where the pathway passes through air-handling spaces, a plenum (OFNP) model must be specified instead; where low smoke and zero halogen are specified, the LSZH version of this identical LC-LC build is supplied. Matching the jacket to the building section is part of the ordering discussion, not an afterthought.

Where armored duplex cords are deployed

The typical homes for this cord are data center cross-connect fields, campus backbone handoffs, industrial control rooms and any pathway shared with power cabling or foot traffic. In each case the pattern is the identical: the path is fixed, the cord is handled during every reconfiguration, and an unprotected jumper would eventually be crushed, kinked or chewed. The armored build removes that failure mode without changing how the cord dresses or connects.

Standard lengths plus custom builds

Standard offerings are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Bespoke lengths beyond this range are manufactured to order. The identical build can further be supplied with black or white jackets, APC polish, or alternative connectors through the customized duplex armored cable program. Specifying the precise path length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.

Factory quality control and testing

Every supplied assembly is terminated with precision zirconia ferrule connectors and measured for insertion loss and return loss before packing. The 0.3dB insertion loss ceiling and 50dB minimum return loss are verified values, not design targets. End-face geometry is checked to keep the physical contact consistent across repeat mating, and the ferrules are rated for up to one thousand insertion cycles, which matters in patching fields that are reconfigured frequently.

Purchase and Factory Support

Refer to the LC-LC OS2 duplex armored series when purchasing a quotation and state the path length, jacket rating and connector polish requested. For non-standard combinations of length, color, connector or jacket, send the specification with the request and the factory will ensure the manufacturable specification before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support