LC UPC to LC UPC Duplex Switchable Uniboot OM3 Fiber Patch Cable

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This OM3 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OM3 glass and optically tested as a complete unit. The uniboot build places both fibers of the duplex connection inside a single round 2.0mm cord with one combined connector housing, halving the supplied cable count in density-optimized panels and simplifying polarity management.
Product Highlights
- Uniboot Allows One Cable to Carry Two Fibers to Reduce Cable Congestion in High-Density Patch Fields
- Bend Insensitive Fiber with 7.5mm Min. Bend Radius
- Allow for Easy Reverse Polarity Without Special Tools
- Termination Is Tested to Ensure Network Performance
- Designed for High-Density Fiber Cabling in Network Cabinet Connections, Ceiling Wiring and Under-Floor Wiring in a Data Center
Specifications
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | Bend Insensitive Fiber |
| Fiber Mode | OM3 50/125μm |
| Wavelength | 850/1300nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Tensile Strength | 60/100N (Long/Short Term) |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.2dB |
| Return Loss | ≥30dB |
| Attenuation at 850nm | ≤3.5dB/km |
| Attenuation at 1300nm | ≤1.5dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70℃ (-4 to 158℉) |
| Fiber Grade | Bend Insensitive Fiber |
| Flame Rating | Riser (OFNR) |
| Insertion Loss | ≤0.2dB |
| Min. Bend Radius (Fiber Cable) | 20/10 |
OM3 for existing multimode plants
This OM3 unit matches the installed base of OM3 link cabling: 10G links to 300 meters and 40/100G SR4 links to 70 meters. When the permanent connection is OM3, patching with OM3 keeps the link specification homogeneous and the test reports clean.
Keeping multimode links healthy
Multimode links fail more frequently from contamination than from fiber damage. Every ferrule must be inspected and cleaned before plugging in, and the dust caps should stay on until the moment of interface. These habits matter more than any specification on the datasheet.
One cord, two fibers
The uniboot design merges the duplex pair into a single round cord and a single connector housing. In a 400G row where every QSFP-DD port consumes a duplex connection, halving the cord count visibly changes the airflow and the manageability of the patching field.
Length Options
Standard offerings cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), with customized length supplied beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the installed connectors.
Quality Control and Testing
Every supplied assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The supplied cable ships with dust caps on both connectors and the test result supplied on order.
Ordering and Factory Support
Refer to this setup by connector pair, fiber mode and length when purchasing a quotation. For configurations outside the listed options, mixed connector families, jackets, labeling or project packaging, send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.