LC UPC to LC UPC Duplex Flat Clip Uniboot OS2, 2.0mm, ofnr Fiber Patch Cable

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This OS2 fiber patch cable carries a LC UPC interface on one end and a LC UPC interface on the other, factory terminated on OS2 glass and optically tested as a complete unit. The uniboot build places both fibers of the duplex connection inside a single round 2.0mm cord with one combined connector housing, halving the supplied cable count in density-optimized panels and simplifying polarity management.
Product Highlights
- Uniboot Allows One Cable to Carry Two Fibers to Reduce Cable Congestion in High-Density Patch Fields
- G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
- Flat Clip Design Provides Additional Space Between Connectors and Improves Airflow
- Reverse Polarity without Exposing the Fibers or Needing Any Tools
- Termination Is Tested to Ensure Network Performance
Specifications
| Fiber Count | 2 Fibers |
|---|---|
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Tensile Strength | 60/100N (Long/Short Term) |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Insertion Loss | ≤0.2dB |
| Return Loss | ≥50dB |
| Attenuation at 1310nm | ≤0.4dB/km |
| Attenuation at 1550nm | ≤0.3dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70℃ (-4 to 158℉) |
Connector and polish choices in the single-mode plant
The OS2 interface on this jumper follows the polish discipline of the network it serves. Because mixing polishes on a mated pair destroys the return loss and can damage the ferrules, the patch side should be matched to the rack-mounted panel side exactly. When the documentation is unclear, the boot color and the connector being used housing tell the truth: green for APC, blue or beige for UPC.
Bend tolerance in real cabinets
Patch fields are rarely kind to fiber. Patch cords path through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in this optical assembly tolerates a 10mm fiber bend radius; thus, a hurried routing decision during a night servicing window does not automatically turn into a measurable penalty on the connection.
Polarity without re-terminating
Uniboot connectors expose the polarity through the housing rather than the termination: the latches or clips let the installer swap the fiber positions without opening the cord. A polarity mistake discovered at turn-up becomes a two-minute correction instead of a replacement order. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.
Length Options
Standard offerings cover the common patching routes: 0.5m (1.6ft), 1m (3ft), 1.5m (5ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), with customized length supplied beyond the list. Specifying the measured path length keeps the slack out of the manager and the strain off the installed connectors.
Quality Control and Testing
Every supplied assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. The supplied cable ships with dust caps on both connectors and the test result supplied on order.
Ordering and Factory Support
Refer to this setup by connector pair, fiber mode and length when purchasing a quotation. For configurations outside the listed options, mixed connector families, jackets, labeling or project packaging, send the specification with the request and the factory will ensure the build before fabrication. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.