H3C LSWM1QSTK1 Compatible 40G QSFP+ Passive Copper Cable, 3m (10ft)

For a direct equipment connection requiring H3C LSWM1QSTK1, this page supplies the 3m (10ft) version with QSFP+ to QSFP+. The cable supports 40G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.
OEM Part Number: LSWM1QSTK1HT Part Number: LSWM1QSTK1
Product Highlights
- Compatible alternative to H3C LSWM1QSTK1
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to QSFP+
- Fixed length and part number: 3m (10ft), LSWM1QSTK1
- Conductor specification: 30AWG
- Minimum bend radius: 35mm
Specifications
| HT Part Number | LSWM1QSTK1 |
|---|---|
| H3C Compatible | LSWM1QSTK1 |
| Manufacturer | HT |
| Connector Type | QSFP+ to QSFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 35mm |
| Wire AWG | 30AWG |
| Cable Length | 3m (9.84ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, QSFP+ MSA and IEEE 802.3ba |
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, QSFP+ MSA and IEEE 802.3ba. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
Position Within the Length Range
LSWM1QSTK1 occupies the middle of this family between LSWM1QSTK0 at 1m (3ft) and LSWM1QSTK2 at 5m (16ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the jacket material is PVC (OFNR).
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.
H3C Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original H3C cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies H3C LSWM1QSTK1.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.