H3C LSWM1QSTK5 Compatible 40G QSFP+ to 4 x 10G SFP+ Passive Copper Breakout Cable, 5m (16ft)

The LSWM1QSTK5 compatible DAC cable provides 40G connectivity for H3C equipment over a fixed 5m (16ft) assembly. Both ends use the stated QSFP+ to 4 SFP+ arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.
OEM Part Number: LSWM1QSTK5HT Part Number: LSWM1QSTK5
Product Highlights
- Compatible alternative to H3C LSWM1QSTK5
- 40G connectivity at 40Gbps
- Interface configuration: QSFP+ to 4 SFP+
- Fixed length and part number: 5m (16ft), LSWM1QSTK5
- Conductor specification: 26AWG
- Minimum bend radius: 26mm
Specifications
| HT Part Number | LSWM1QSTK5 |
|---|---|
| H3C Compatible | LSWM1QSTK5 |
| Manufacturer | HT |
| Connector Type | QSFP+ to 4 SFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 26mm |
| Wire AWG | 26AWG |
| Cable Length | 5m(16.4ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, SFF-8431 and QSFP+ MSA |
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 5m (16ft) length gives LSWM1QSTK5 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
Position Within the Length Range
LSWM1QSTK5 is the longest of 3 verified length options in this family. Compared with LSWM1QSTK4 at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 26mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431 and QSFP+ MSA. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Volume orders can include customer references on the labels and carton list.
H3C Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original H3C cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies H3C LSWM1QSTK5.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.