Tanzania Fiber Optics

fiber optic products manufacturing since 1995

NVIDIA/Mellanox MCA4J80-N005 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top InfiniBand NDR Active Copper Twinax Cable, 5m (16ft)

NVIDIA/Mellanox MCA4J80-N005 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top InfiniBand NDR Active Copper Twinax Cable, 5m (16ft)

The MCA4J80-N005 compatible ACC cable provides 800G connectivity for NVIDIA/Mellanox equipment over a fixed 5m (16ft) assembly. Both ends use the stated OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.

OEM Part Number: MCA4J80-N005HT Part Number: MCA4J80-N005

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA4J80-N005
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 5m (16ft), MCA4J80-N005
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 26AWG
  • Maximum power consumption: 1.3W Per End
  • Minimum bend radius: 59.5mm

Specifications

HT Part NumberMCA4J80-N005
NVIDIA/Mellanox InfiniBand CompatibleMCA4J80-N005
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length5m (16ft)
Wire AWG26AWG
Minimum Bend Radius59.5mm
Max. Power Consumption1.3W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4
Application800G InfiniBand
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP Rev5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The 5m (16ft) length gives MCA4J80-N005 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.

Position Within the Length Range

MCA4J80-N005 is the longest of 3 verified length options in this family. Compared with MCA4J80-N004 at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 59.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 59.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.

NVIDIA/Mellanox Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4J80-N005.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

You are here: Home 100BASE SFP NVIDIA/Mellanox MCA4J80-N005 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top InfiniBand NDR Active Copper Twinax Cable, 5m (16ft)