NVIDIA/Mellanox MCA7J60-N004 Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Ethernet Active Copper Breakout Cable, 4m (13ft)

This 4m (13ft) ACC assembly is made for installations that call for NVIDIA/Mellanox MCA7J60-N004 at 800G. The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: MCA7J60-N004HT Part Number: MCA7J60-N004
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCA7J60-N004
- 800G connectivity at 800Gbps
- Interface configuration: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
- Fixed length and part number: 4m (13ft), MCA7J60-N004
- Cable construction: Active Breakout DAC (ACC)
- Conductor specification: 26AWG
- Maximum power consumption: 1.5W (800G End)/0.6W (400G Per End)
- Minimum bend radius: 40mm
Specifications
| HT Part Number | MCA7J60-N004 |
|---|---|
| NVIDIA/Mellanox Ethernet Compatible | MCA7J60-N004 |
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 4m (13ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 40mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 1.5W (800G End)/0.6W (400G Per End) |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PMA4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA, CMIS 5.0, IEEE 802.3 ck |
Signal and Lane Configuration
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PMA4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS 5.0, IEEE 802.3 ck. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Length Selection and Installation Planning
The 4m (13ft) length gives MCA7J60-N004 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
MCA7J60-N004 is the longest of 4 verified length options in this family. Compared with MCA7J60-N003 at 3m (10ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W (800G End)/0.6W (400G Per End); the jacket material is PET.
Power and Thermal Planning
The rated power consumption is 1.5W (800G End)/0.6W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.
NVIDIA/Mellanox Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J60-N004.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. MCA7J60-N004 refers here to 4m (13ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Keep MCA7J60-N004 associated with 4m (13ft) throughout the order and receiving record.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.