NVIDIA/Mellanox MCA7J70-N005 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top Ethernet Active Copper Breakout Cable, 5m (16ft)

This 5m (16ft) ACC assembly is made for installations that call for NVIDIA/Mellanox MCA7J70-N005 at 800G. The OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: MCA7J70-N005HT Part Number: MCA7J70-N005
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCA7J70-N005
- 800G connectivity at 850Gbps (8x 106.25Gbps)
- Interface configuration: OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top)
- Fixed length and part number: 5m (16ft), MCA7J70-N005
- Cable construction: Active Breakout DAC (ACC)
- Conductor specification: 26AWG
- Maximum power consumption: 1.7W (800G End)0.3W (200G Per End)
- Minimum bend radius: 32.5mm
Specifications
| HT Part Number | MCA7J70-N005 |
|---|---|
| NVIDIA/Mellanox Ethernet Compatible | MCA7J70-N005 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top) |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 5m (16ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 32.5mm |
| Max. Power Consumption | 1.7W (800G End)0.3W (200G Per End) |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Quad 2x100G-PAM4 |
| Application | 800G/200G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev 5.0 |
Signal and Lane Configuration
The listed modulation format is 8x100G-PAM4 to Quad 2x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Length Selection and Installation Planning
The 5m (16ft) length gives MCA7J70-N005 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
Position Within the Length Range
MCA7J70-N005 is the longest of 5 verified length options in this family. Compared with MCA7J70-N004 at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.7W (800G End)0.3W (200G Per End); the jacket material is PET.
Power and Thermal Planning
The rated power consumption is 1.7W (800G End)0.3W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G/200G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev 5.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The OSFP (IHS/Finned Top) to 4x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
NVIDIA/Mellanox Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J70-N005.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.