Tanzania Fiber Optics

fiber optic products manufacturing since 1995

NVIDIA/Mellanox MCP7Y10-N00A Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 InfiniBand NDR Passive Copper Breakout Cable, 0.5m (2ft)

NVIDIA/Mellanox MCP7Y10-N00A Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 InfiniBand NDR Passive Copper Breakout Cable, 0.5m (2ft)

For a direct equipment connection requiring NVIDIA/Mellanox MCP7Y10-N00A, this page supplies the 0.5m (2ft) version with OSFP (IHS/Finned Top) to 2x QSFP112. The cable supports 800G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.

OEM Part Number: MCP7Y10-N00AHT Part Number: MCP7Y10-N00A

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7Y10-N00A
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP112
  • Fixed length and part number: 0.5m (2ft), MCP7Y10-N00A
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (OSFP End)0.1W (QSFP112 Per End)
  • Minimum bend radius: 34.5mm

Specifications

HT Part NumberMCP7Y10-N00A
NVIDIA/Mellanox InfiniBand CompatibleMCP7Y10-N00A
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP112
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length0.5m (2ft)
Jacket MaterialPVC
Minimum Bend Radius34.5mm
Wire AWG30AWG
Max. Power Consumption0.1W (OSFP End)0.1W (QSFP112 Per End)
Modulation FormatOSFP-8x 100G-PAM4QSFP112-4x 100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G InfiniBand
ProtocolsOSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0

Signal and Lane Configuration

The listed modulation format is OSFP-8x 100G-PAM4QSFP112-4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 34.5mm; the stated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G InfiniBand. Listed interface and protocol references include OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing MCP7Y10-N00A; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

MCP7Y10-N00A is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCP7Y10-N001 at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Volume orders can include customer references on the labels and carton list.

NVIDIA/Mellanox Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7Y10-N00A.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to MCP7Y10-N00A.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP NVIDIA/Mellanox MCP7Y10-N00A Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 InfiniBand NDR Passive Copper Breakout Cable, 0.5m (2ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support