Tanzania Fiber Optics

fiber optic products manufacturing since 1995

NVIDIA/Mellanox MFA7U10-H005-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 5m (16ft)

NVIDIA/Mellanox MFA7U10-H005-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 5m (16ft)

This 5m (16ft) AOC assembly is made for installations that call for NVIDIA/Mellanox MFA7U10-H005-FLT at 400G. The OSFP (RHS/Flat Top) to 2x QSFP56 connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.

OEM Part Number: MFA7U10-H005-FLTHT Part Number: MFA7U10-H005-FLT

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MFA7U10-H005-FLT
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to 2x QSFP56
  • Fixed length and part number: 5m (16ft), MFA7U10-H005-FLT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberMFA7U10-H005-FLT
NVIDIA/Mellanox InfiniBand CompatibleMFA7U10-H005-FLT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length5m (16ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation Format8x 50G-PAM4 to Dual 4x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsCMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Dual 4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include CMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (RHS/Flat Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The 5m (16ft) length gives MFA7U10-H005-FLT more freedom for adjacent-rack and row-end deployments. The integrated optical assembly should be supported along its route without tight bends or connector pull loads; the AOC specification and host support must still match the intended link.

Position Within the Length Range

MFA7U10-H005-FLT occupies the middle of this family between MFA7U10-H003-FLT at 3m (10ft) and MFA7U10-H010-FLT at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

NVIDIA/Mellanox Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7U10-H005-FLT.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

You are here: Home 100BASE SFP NVIDIA/Mellanox MFA7U10-H005-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 5m (16ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support