MTP-12 APC Female to Unterminated Pigtail Trunk Cable, 144 Fibers, OS2

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: MTP-12 APC Female to Unterminated Pigtail Trunk Cable, OS2 glass, with a factory-polished MTP APC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber path into a documented, testable port. The MTP interface carries twelve fibers on one connector; thus, a single splice operation terminates a full parallel-optics trunk location. At 144 fibers, one unit replaces a dozen individual pigtail sets on the distribution frame.
Product Highlights
- LSZH Fire Safety-Rated Ensures Safety in Indoor Environments
- Double Jacket Ensures Durability and Performance in Long-distance Links
- Used to Ensure Efficient Use of Space and Rapid Network Deployment
- US Conec MTP® Connector with Optimal 0.35dB Low IL
- G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
Specifications
| Connector A | US Conec MTP® Elite Female (Non-Pinned) |
|---|---|
| Connector B | Unterminated |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC |
| Cable Jacket | LSZH |
| Fiber Count | 144 Fibers (Base-12) |
| Minimum Bend Radius | 10mm |
| Breakout Outside Diameter (OD) | 2.0mm |
| Tensile Strength | 200/660N (Long/Short Term) |
| Breakout Length | 0.84m |
| Insertion Loss | ≤0.35dB |
| Return Loss | ≥65dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Connector A | MTP®-12 APC (Female) |
Why pigtails remain the standard termination
A pigtail is half an interface: one end is a factory-assembled connector, polished and tested under procedure control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the installed cable brings the connector being used quality of the factory to a field path. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the path length is uncertain or the pathway is difficult to pre-measure.
Fusion splicing practice that protects the budget
A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.
Color coding as a working discipline
Twelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. Because the strands in this set observe the standard sequence, the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the identical sequence, a fault on location seven months from now is found in minutes rather than traced strand by strand.
Keeping twelve-fiber splices organized
Multi-fiber splicing rewards method: complete one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress each finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads visibly is a tray that gets re-entered without new faults.
MTP pigtails for parallel-optics positions
Parallel-optics trunks arrive as multi-fiber cables and must become MTP ports on the rack-mounted panel. A twelve-fiber MTP pigtail makes that conversion in one splice operation per trunk tube: the twelve strands splice onto the backbone, and the factory-polished MTP interface presents the full dozen lanes as a single port. Per-lane documentation follows the fiber positions, keeping polarity and mapping unambiguous for the transceivers that will mate with the rack-mounted panel.
High-count pigtail trunks at the frame
Whereas one pigtail trunk carries the full count in a single jacketed unit with twelve MTP interfaces, at 144 fibers the economics of splicing change: twelve individual pigtail sets would occupy twelve separate dressing routes across the frame. The backbone cable splices strand by strand in the tray as always, but the rack-mounted panel side arrives as twelve finished ports. For dense ODF positions this build halves the dressing work and keeps the frame readable.
Bend-insensitive glass in dense trays
Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning.
A splicing workflow that scales
Productive termination crews work to a fixed routine: mount the tray, dress the supplied cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency further makes quality auditable - identical materials, identical sequence, identical pass criteria across every site.
Sparing and kit planning for termination work
Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may generally be ordered to the identical specification.
Factory Quality Control and Testing
Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results supplied on order.
Purchase and Factory Support
Refer to this pigtail by connector, polish, fiber mode, fiber count and build when purchasing a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the specification with the request and the factory will ensure the manufacturable specification. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.