Cisco OSFP-800G-2OFLAE Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Electrical Copper Breakout Cable

A 800G direct-attached link depends on the correct host identity, interface mode and physical length. This page covers the Cisco OSFP-800G-2OFLAE compatible AEC series in OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top), including 5m (16ft). Each documented length-specific OEM reference is linked separately where an individual product page is available.
Series Part Number: OSFP-800G-2OFLAEHT Part Number: OSFP-800G-2OFLAE
Product Highlights
- HT-manufactured compatible alternative for Cisco OSFP-800G-2OFLAE
- 800G aggregate connectivity at 800Gbps
- Interface configuration: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
- Active Breakout DAC (AEC) / Copper
- Length configurations covered: 5m (16ft)
- Conductor specification: 28AWG
- Power consumption: 12W (800G End)10W (400G Per End)
- Operating temperature: 0 to 70°C (32 to 158°F)
Available Lengths and Corresponding Part Numbers
The documented series configuration is 5m (16ft). Use the relevant OEM reference below together with the HT identity and required length when requesting a quotation. If another length carries a different OEM part number, it must be reviewed and ordered as that distinct configuration.
Compatible OEM Part Numbers
- OSFP-800G-2OFLAE05
Specifications
| HT Part Number | OSFP-800G-2OFLAE |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (AEC) |
| Cable Length Options Covered | 5m (16ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 38mm |
| Wire AWG | 28AWG |
| Max. Power Consumption | 12W (800G End)10W (400G Per End) |
| Modulation Format | 8x100G-PAM4 to Dual 4x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0 |
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this series, keep the interface rate, AEC construction and length-specific OEM reference together throughout that review.
Applications and Deployment
For an AEC connection, matching the connector shape is only the first step. The host must support the electrical signaling, retiming behavior and aggregate rate of the complete assembly. Thermal planning is particularly important when many active ends populate adjacent ports. For this series, the listed interface is OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) and the aggregate rate is 800G. The stated application is 800G/400G Ethernet.
Cable Construction and Routing
The specification table records the conductor specification is 28AWG; the jacket material is PET; the minimum bend radius is 38mm; the operating temperature is 0 to 70°C (32 to 158°F); the power consumption is 12W (800G End)10W (400G Per End). Use those values when preparing the rack pathway and receiving checklist. Do not pull a connector by its cable, compress the run under tight ties or force excess length into a sharp coil. Connector protection should remain in place until the assembly is ready for insertion.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Both connector ends are inspected as part of the complete assembly, and protective packing is selected to avoid tight bends during transport and storage.
Cisco Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Series-level inspection is followed by the exact length and OEM configuration selected for dispatch. Functional verification includes link establishment and diagnostic indications where the host exposes them.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. For this series, follow the corresponding length link, quote that exact OEM part number and keep different lengths on separate order lines. HT part number OSFP-800G-2OFLAE identifies the product family; the linked page provides the final length-specific identity.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.
Frequently Asked Questions
Is this an original Cisco cable?
No. It is an HT-manufactured compatible cable for equipment that specifies OSFP-800G-2OFLAE, not an original Cisco-branded product.
Are different lengths and OEM part numbers separate products?
Yes. Where a length has its own OEM reference, follow the corresponding link above and order that exact part number on its own line. Do not substitute another length only because the connector arrangement is the same.
Does this AEC cable require separate modules at each end?
No. The connector ends and cable form one complete direct-attach assembly. The ends are not detachable standalone transceivers, and the complete product is tested together.
What information helps confirm compatibility?
Provide the equipment manufacturer and model, port type, hardware revision and software release, together with the required OEM reference, length and quantity. Breakout projects should also identify the intended lane configuration.
