Tanzania Fiber Optics

fiber optic products manufacturing since 1995

OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 Passive Copper Breakout Cable, 1m (3ft)

OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 Passive Copper Breakout Cable, 1m (3ft)

This 1m (3ft) DAC assembly is made for installations that call for Generic OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT at 800G. The OSFP (IHS/Finned Top) to 2x QSFP112 connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.

OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP112
  • Fixed length and part number: 1m (3ft), OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (OSFP End)0.1W (QSFP112 Per End)
  • Minimum bend radius: 40.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP112
Max. Data Rate800Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length1m (3ft)
Jacket MaterialPVC
Minimum Bend Radius40.5mm
Wire AWG28AWG
Max. Power Consumption0.1W (OSFP End)0.1W (QSFP112 Per End)
Modulation FormatOSFP-8x 100G-PAM4QSFP112-4x 100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0

Signal and Lane Configuration

The listed modulation format is OSFP-8x 100G-PAM4QSFP112-4x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-0.5M2FT at 0.5m (2ft) and OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP OSFP (IHS/Finned Top) to 2x QSFP112-800G-DAC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 Passive Copper Breakout Cable, 1m (3ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support