OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 IHS/Finned Top Passive Copper Breakout Cable, 0.5m (2ft)

This 0.5m (2ft) DAC assembly is made for installations that call for Generic OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT at 800G. The OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FTHT Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT
Product Highlights
- HT-manufactured DAC assembly in 0.5m (2ft)
- 800G connectivity at 800Gbps
- Interface configuration: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)
- Fixed length and part number: 0.5m (2ft), OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT
- Cable construction: Passive Breakout DAC
- Conductor specification: 30AWG
- Maximum power consumption: 0.1W (800G End), 0.1W (200G Per End)
- Minimum bend radius: 26mm
Specifications
| HT Part Number | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 0.5m (5ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 26mm |
| Max. Power Consumption | 0.1W (800G End), 0.1W (200G Per End) |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Quad 2x100G-PAM4 |
| Application | 800G/200G Ethernet |
| Protocols | OSFP MSA, CMIS Rev4.0, IEEE 802.3ck |
Signal and Lane Configuration
The listed modulation format is 8x100G-PAM4 to Quad 2x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 26mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 800G/200G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS Rev4.0, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
Position Within the Length Range
OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-0.5M2FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 26mm; the stated power consumption is 0.1W (800G End), 0.1W (200G Per End); the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is 0.1W (800G End), 0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.
Generic Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
