OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top Active Copper Twinax Cable, 1.1m (3.6ft)

This 1.1m (3.6ft) ACC assembly is made for installations that call for Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT at 1.6T. The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT
Product Highlights
- HT-manufactured ACC assembly in 1.1m (3.6ft)
- 1.6T connectivity at 1600Gbps
- Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
- Fixed length and part number: 1.1m (3.6ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT
- Cable construction: Active DAC (ACC)
- Conductor specification: 30AWG
- Maximum power consumption: 2W Per End
- Minimum bend radius: 50mm
Specifications
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 1600Gbps |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 1.1m (3.6ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 50mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 2W Per End |
| Modulation Format | 8x 200G-PAM4 to 8x 200G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 1.6T Ethernet |
| Protocols | OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0 |
Signal and Lane Configuration
The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Network and Protocol Considerations
The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
Length Selection and Installation Planning
The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
Position Within the Length Range
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT at 1.5m (5ft), adding 0.4m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 50mm; the stated power consumption is 2W Per End; the jacket material is PET.
Power and Thermal Planning
The rated power consumption is 2W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 50mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Generic Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
