Tanzania Fiber Optics

fiber optic products manufacturing since 1995

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 50m (164ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 50m (164ft)

The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT compatible AOC cable provides 800G connectivity for Generic equipment over a fixed 50m (164ft) assembly. Both ends use the stated OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT

Product Highlights

  • HT-manufactured AOC assembly in 50m (164ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 50m (164ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 14W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
Cable Length50m (164ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption14W Per End
Modulation Format8x 100G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

For this 50m (164ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. The next shorter verified assembly is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-30M98FT at 30m (98ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT is the longest of 10 verified length options in this family. Compared with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-30M98FT at 30m (98ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 14W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 14W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT refers here to 50m (164ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

You are here: Home 100BASE SFP OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-800G-AOC-50M164FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 50m (164ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support