The QDD-2X200G-AOC-25M compatible AOC cable provides 400G connectivity for Juniper Networks equipment over a fixed 25m (82ft) assembly. Both ends use the stated QSFP-DD to 2x QSFP56 arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.

OEM Part Number: QDD-2X200G-AOC-25MHT Part Number: QDD-2X200G-AOC-25M

Product Highlights

  • Compatible alternative to Juniper Networks QDD-2X200G-AOC-25M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 2x QSFP56
  • Fixed length and part number: 25m (82ft), QDD-2X200G-AOC-25M
  • Cable construction: Breakout AOC
  • Maximum power consumption: 12W (QSFP-DD End)5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQDD-2X200G-AOC-25M
Juniper Networks CompatibleQDD-2X200G-AOC-25M
ManufacturerHT
Form FactorQSFP-DD to 2x QSFP56
Max. Data Rate400Gbps
Cable Length25m (82ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption12W (QSFP-DD End)5.5W (QSFP56 Per End)
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Breakout Port Mapping

The QSFP-DD to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

With 25m (82ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. Within this family, QDD-2X200G-AOC-20M is shorter at 20m (66ft), while QDD-2X200G-AOC-30M is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QDD-2X200G-AOC-25M occupies the middle of this family between QDD-2X200G-AOC-20M at 20m (66ft) and QDD-2X200G-AOC-30M at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 12W (QSFP-DD End)5.5W (QSFP56 Per End); the jacket material is OFNP.

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 12W (QSFP-DD End)5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, IEEE 802.3bs, QSFP-DD MSA, SFF-8024, SFF-8679, SFF-8665, CMIS 4.0, OIF-CEI-04.0. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

Juniper Networks Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-2X200G-AOC-25M.

Does this order code cover multiple lengths?

No. QDD-2X200G-AOC-25M refers here to 25m (82ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Keep QDD-2X200G-AOC-25M associated with 25m (82ft) throughout the order and receiving record.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP Juniper Networks QDD-2X200G-AOC-25M Compatible 400G QSFP-DD 8 x 50G PAM4 to 2 x 200G QSFP56 4 x 50G PAM4 Ethernet Active Optical Breakout Cable, 25m (82ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support