Juniper Networks QDD-4X100G-AOC-5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 5m (16ft)

For a direct equipment connection requiring Juniper Networks QDD-4X100G-AOC-5M, this page supplies the 5m (16ft) version with QSFP-DD to 4x QSFP28. The cable supports 400G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.
OEM Part Number: QDD-4X100G-AOC-5MHT Part Number: QDD-4X100G-AOC-5M
Product Highlights
- Compatible alternative to Juniper Networks QDD-4X100G-AOC-5M
- 400G connectivity at 400Gbps
- Interface configuration: QSFP-DD to 4x QSFP28
- Fixed length and part number: 5m (16ft), QDD-4X100G-AOC-5M
- Cable construction: Breakout AOC
- Maximum power consumption: 10W (QSFP-DD End)5.5W (QSFP28 Per End)
- Minimum bend radius: 30mm
Specifications
| HT Part Number | QDD-4X100G-AOC-5M |
|---|---|
| Juniper Networks Compatible | QDD-4X100G-AOC-5M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to 4x QSFP28 |
| Max. Data Rate | 400Gbps |
| Cable Length | 5m (16ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W (QSFP-DD End)5.5W (QSFP28 Per End) |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | QSFP-DD-8x 50G-PAM4QSFP28-4x 25G-NRZ |
| DDM/DOM | Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8661, IEEE802.3bs-400GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636 |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Signal and Lane Configuration
The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 10W (QSFP-DD End)5.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE802.3bs-400GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP-DD to 4x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Integrated Optical Assembly
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Length Selection and Installation Planning
The 5m (16ft) length gives QDD-4X100G-AOC-5M more freedom for adjacent-rack and row-end deployments. The integrated optical assembly should be supported along its route without tight bends or connector pull loads; the AOC specification and host support must still match the intended link.
Position Within the Length Range
QDD-4X100G-AOC-5M occupies the middle of this family between QDD-4X100G-AOC-3M at 3m (10ft) and QDD-4X100G-AOC-7M at 7m (23ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End)5.5W (QSFP28 Per End); the jacket material is OFNP.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Juniper Networks Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QDD-4X100G-AOC-5M.
Does this order code cover multiple lengths?
No. QDD-4X100G-AOC-5M refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.