Juniper Networks QFX-SFP-DAC-7MA Compatible 10G SFP+ Active Copper Twinax Cable, 7m (23ft)

This 7m (23ft) DAC assembly is made for installations that call for Juniper Networks QFX-SFP-DAC-7MA at 10G. The SFP+ to SFP+ connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: QFX-SFP-DAC-7MAHT Part Number: QFX-SFP-DAC-7MA
Product Highlights
- Compatible alternative to Juniper Networks QFX-SFP-DAC-7MA
- 10G connectivity at 10Gbps
- Interface configuration: SFP+ to SFP+
- Fixed length and part number: 7m (23ft), QFX-SFP-DAC-7MA
- Cable construction: Active Twinax
- Conductor specification: 26AWG
- Maximum power consumption: ≤0.5W
- Minimum bend radius: 30mm
Specifications
| HT Part Number | QFX-SFP-DAC-7MA |
|---|---|
| Juniper Networks Compatible | QFX-SFP-DAC-7MA |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Minimum Bend Radius | 30mm |
| Wire AWG | 26AWG |
| Cable Length | 7m (22.97ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Active Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
Extended reach changes the installation checks for QFX-SFP-DAC-7MA. Confirm that 7m (23ft) follows the intended route without tension, then verify that intermediate supports do not squeeze the jacket or hide the connectors behind adjacent cables. Both hosts must still match the stated interface and lane configuration. Within this family, EX-SFP-10GE-DAC-5MA is shorter at 5m (16ft), while EX-SFP-10GE-DAC-10MA is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Position Within the Length Range
QFX-SFP-DAC-7MA occupies the middle of this family between EX-SFP-10GE-DAC-5MA at 5m (16ft) and EX-SFP-10GE-DAC-10MA at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Juniper Networks Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks QFX-SFP-DAC-7MA.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Does this order code cover multiple lengths?
No. QFX-SFP-DAC-7MA refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 7m (23ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.