Tanzania Fiber Optics

fiber optic products manufacturing since 1995

QSFP-DD to 4x QSFP28-400G-AOC-20M66FT 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 20m (66ft)

QSFP-DD to 4x QSFP28-400G-AOC-20M66FT 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 20m (66ft)

This 20m (66ft) AOC assembly is made for installations that call for Generic QSFP-DD to 4x QSFP28-400G-AOC-20M66FT at 400G. The QSFP-DD to 4x QSFP28 connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.

OEM Part Number: QSFP-DD to 4x QSFP28-400G-AOC-20M66FTHT Part Number: QSFP-DD to 4x QSFP28-400G-AOC-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 4x QSFP28
  • Fixed length and part number: 20m (66ft), QSFP-DD to 4x QSFP28-400G-AOC-20M66FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (QSFP-DD End)5.5W (QSFP28 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberQSFP-DD to 4x QSFP28-400G-AOC-20M66FT
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP28
Max. Data Rate400Gbps
Cable Length20m (66ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption10W (QSFP-DD End)5.5W (QSFP28 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP28-4x 25G-NRZ
DDM/DOMSupported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8661, IEEE802.3bs-400GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End)5.5W (QSFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (QSFP-DD End)5.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8661, IEEE802.3bs-400GAUI-8, IEEE802.3bm-CAUI-4, CMIS 4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

For this 20m (66ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. The next shorter verified assembly is QSFP-DD to 4x QSFP28-400G-AOC-15M49FT at 15m (49ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP-DD to 4x QSFP28-400G-AOC-20M66FT is the longest of 8 verified length options in this family. Compared with QSFP-DD to 4x QSFP28-400G-AOC-15M49FT at 15m (49ft), it provides 5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Keep QSFP-DD to 4x QSFP28-400G-AOC-20M66FT associated with 20m (66ft) throughout the order and receiving record.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

You are here: Home 100BASE SFP QSFP-DD to 4x QSFP28-400G-AOC-20M66FT 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 20m (66ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support