Tanzania Fiber Optics

fiber optic products manufacturing since 1995

QSFP-DD to 8x SFP28-200G-DAC-1M3FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

QSFP-DD to 8x SFP28-200G-DAC-1M3FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

The QSFP-DD to 8x SFP28-200G-DAC-1M3FT compatible DAC cable provides 200G connectivity for Generic equipment over a fixed 1m (3ft) assembly. Both ends use the stated QSFP-DD to 8x SFP28 arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.

OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-1M3FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 8x SFP28
  • Fixed length and part number: 1m (3ft), QSFP-DD to 8x SFP28-200G-DAC-1M3FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP28 Per End)
  • Minimum bend radius: 20.5mm

Specifications

HT Part NumberQSFP-DD to 8x SFP28-200G-DAC-1M3FT
ManufacturerHT
Form FactorQSFP-DD to 8x SFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius20.5mm
Wire AWG30AWG
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZSFP28-25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), QSFP-DD to 8x SFP28-200G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

QSFP-DD to 8x SFP28-200G-DAC-1M3FT occupies the middle of this family between QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT at 0.5m (2ft) and QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 20.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 20.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-DD to 8x SFP28-200G-DAC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP QSFP-DD to 8x SFP28-200G-DAC-1M3FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support