Tanzania Fiber Optics

fiber optic products manufacturing since 1995

QSFP-DD to QSFP-DD-800G-AEC-1M3FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 1m (3ft)

QSFP-DD to QSFP-DD-800G-AEC-1M3FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 1m (3ft)

The QSFP-DD to QSFP-DD-800G-AEC-1M3FT compatible AEC cable provides 800G connectivity for Generic equipment over a fixed 1m (3ft) assembly. Both ends use the stated QSFP-DD to QSFP-DD arrangement. It is inspected and functionally checked before packing, with handling guidance designed to protect the connectors during installation and later service.

OEM Part Number: QSFP-DD to QSFP-DD-800G-AEC-1M3FTHT Part Number: QSFP-DD to QSFP-DD-800G-AEC-1M3FT

Product Highlights

  • HT-manufactured AEC assembly in 1m (3ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 1m (3ft), QSFP-DD to QSFP-DD-800G-AEC-1M3FT
  • Cable construction: Active DAC (AEC)
  • Conductor specification: 32AWG
  • Maximum power consumption: 12W Per End
  • Minimum bend radius: 36.5

Specifications

HT Part NumberQSFP-DD to QSFP-DD-800G-AEC-1M3FT
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive DAC (AEC)
Cable Length1m (3ft)
Jacket MaterialPET
Minimum Bend Radius36.5
Wire AWG32AWG
Max. Power Consumption12W Per End
Modulation Format8x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G Ethernet
ProtocolsCMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

At 1m (3ft), QSFP-DD to QSFP-DD-800G-AEC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

QSFP-DD to QSFP-DD-800G-AEC-1M3FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP-DD to QSFP-DD-800G-AEC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5; the stated power consumption is 12W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 12W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Keep QSFP-DD to QSFP-DD-800G-AEC-1M3FT associated with 1m (3ft) throughout the order and receiving record.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

You are here: Home 100BASE SFP QSFP-DD to QSFP-DD-800G-AEC-1M3FT 800G QSFP-DD 8 x 100G PAM4 Active Electrical Cable, 1m (3ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support