Tanzania Fiber Optics

fiber optic products manufacturing since 1995

QSFP28 to 4x SFP28-100G-AOC-50M164FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 50m (164ft)

QSFP28 to 4x SFP28-100G-AOC-50M164FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 50m (164ft)

This 50m (164ft) AOC assembly is made for installations that call for Generic QSFP28 to 4x SFP28-100G-AOC-50M164FT at 100G. The QSFP28 to 4x SFP28 connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.

OEM Part Number: QSFP28 to 4x SFP28-100G-AOC-50M164FTHT Part Number: QSFP28 to 4x SFP28-100G-AOC-50M164FT

Product Highlights

  • HT-manufactured AOC assembly in 50m (164ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4x SFP28
  • Fixed length and part number: 50m (164ft), QSFP28 to 4x SFP28-100G-AOC-50M164FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W (QSFP28 End)0.8W (SFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP28 to 4x SFP28-100G-AOC-50M164FT
ManufacturerHT
Form FactorQSFP28 to 4x SFP28
Max. Data Rate100Gbps
Cable Length50m (164ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W (QSFP28 End)0.8W (SFP28 Per End)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP28 MSA, SFP28 MSA

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The 50m (164ft) reach of QSFP28 to 4x SFP28-100G-AOC-50M164FT is useful only when the managed pathway requires it; straight-line distance between ports is not a sufficient measurement. Check the route around rack rails, cable managers and maintenance clearances, then protect the integrated optical cable and both optical engines from tight bends and unsupported spans. The next shorter verified assembly is QSFP28 to 4x SFP28-100G-AOC-30M98FT at 30m (98ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP28 to 4x SFP28-100G-AOC-50M164FT is the longest of 11 verified length options in this family. Compared with QSFP28 to 4x SFP28-100G-AOC-30M98FT at 30m (98ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Neutral packaging and customer-specific packing documentation are available on request.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 50m (164ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP QSFP28 to 4x SFP28-100G-AOC-50M164FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 50m (164ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support