Tanzania Fiber Optics

fiber optic products manufacturing since 1995

SC APC to Unterminated Fiber Pigtail, 12 Fibers, Bunch, OS2

SC APC to Unterminated Fiber Pigtail, 12 Fibers, Bunch, OS2

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: SC APC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished SC APC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber path into a documented, testable port.

Product Highlights

  • Easy-strip 900µm Tight-buffered Coating
  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Support Both Fusion and Mechanical Splicing
  • G.657.A1 Bend Insensitive Fiber & 10mm Min. Bend Radius
  • Color-coded for Easy Matching of 0.9mm Fiber to Be Spliced

Specifications

Connector ASC APC Simplex
Connector BUnterminated
Fiber Count12 Fibers
Fiber GradeG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Jacket ColorYellow
Cable JacketPVC (Unrated)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Connector Durability1000 Times
Tensile Strength (Long/Short Term)200/660N
Attenuation at 1310nm0.36dB/km
Attenuation at 1550nm0.22dB/km
Insertion Loss≤0.3dB
Return Loss≥60dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158℉)
Wavelength(1)Color(1)

Why pigtails remain the standard termination

A pigtail is half an interface: one end is a factory-assembled connector, polished and tested under procedure control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the installed cable brings the connector being used quality of the factory to a field path. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the path length is uncertain or the pathway is difficult to pre-measure.

Fusion splicing practice that protects the budget

A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.

Color coding as a working discipline

Twelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. Because the strands in this set observe the standard sequence, the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the identical sequence, a fault on location seven months from now is found in minutes rather than traced strand by strand.

Keeping twelve-fiber splices organized

Multi-fiber splicing rewards method: complete one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress each finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads visibly is a tray that gets re-entered without new faults.

Unjacketed and bunch constructions compared

The unjacketed color-coded set presents twelve separate 0.9mm strands for direct tray work - the lightest build and the easiest to dress. The bunch build gathers the twelve strands under a shared jacket that breaks out near the connector being used end, adding handling protection on the path between the rack-mounted panel and the tray. Select unjacketed where the strands stay inside a protected enclosure; select bunch where the supplied assembly crosses open space between frames.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress the supplied cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency further makes quality auditable - identical materials, identical sequence, identical pass criteria across every site.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may generally be ordered to the identical specification.

Selecting the right pigtail for the job

Five decisions define the order: the connector being used series should be matched to the rack-mounted panel, the polish should be matched to the plant, the fiber mode should be matched to the supplied cable, the build should be matched to the path, and the count should be matched to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the specification sits outside the standard configurations, the customized platforms cover the remaining combinations.

Factory Quality Control and Testing

Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results supplied on order.

Purchase and Factory Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and build when purchasing a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the specification with the request and the factory will ensure the manufacturable specification. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP SC APC to Unterminated Fiber Pigtail, 12 Fibers, Bunch, OS2

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support