Juniper SDD-100G-1M Compatible 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

For a direct equipment connection requiring Juniper SDD-100G-1M, this page supplies the 1m (3ft) version with SFP-DD to SFP-DD. The cable supports 100G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.
OEM Part Number: SDD-100G-1MHT Part Number: SDD-100G-1M
Product Highlights
- Compatible alternative to Juniper SDD-100G-1M
- 100G connectivity at 100Gbps
- Interface configuration: SFP-DD to SFP-DD
- Fixed length and part number: 1m (3ft), SDD-100G-1M
- Cable construction: Passive Twinax
- Conductor specification: 30AWG
- Maximum power consumption: 0.1W
- Minimum bend radius: 23.6mm
Specifications
| HT Part Number | SDD-100G-1M |
|---|---|
| Juniper Compatible | SDD-100G-1M |
| Manufacturer | HT |
| Form Factor | SFP-DD to SFP-DD |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 1m (3ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 23.6mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | 2x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFP-DD MSA, SFP-DD MIS, IEEE 802.3cd |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Signal and Lane Configuration
The listed modulation format is 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23.6mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFP-DD MSA, SFP-DD MIS, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 1m (3ft), SDD-100G-1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
SDD-100G-1M is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SDD-100G-2M at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23.6mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.
Juniper Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Juniper cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper SDD-100G-1M.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
