SFP-DD to 2x SFP56-100G-DAC-3M10FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

For a direct equipment connection requiring Generic SFP-DD to 2x SFP56-100G-DAC-3M10FT, this page supplies the 3m (10ft) version with SFP-DD to 2x SFP56. The cable supports 100G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.
OEM Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FTHT Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FT
Product Highlights
- HT-manufactured DAC assembly in 3m (10ft)
- 100G connectivity at 100Gbps
- Interface configuration: SFP-DD to 2x SFP56
- Fixed length and part number: 3m (10ft), SFP-DD to 2x SFP56-100G-DAC-3M10FT
- Cable construction: Passive Twinax
- Conductor specification: 26AWG
- Maximum power consumption: 0.1W
- Minimum bend radius: 28.8mm
Specifications
| HT Part Number | SFP-DD to 2x SFP56-100G-DAC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP-DD to 2x SFP56 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 3m (10ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 28.8mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd |
Signal and Lane Configuration
The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Position Within the Length Range
SFP-DD to 2x SFP56-100G-DAC-3M10FT is the longest of 4 verified length options in this family. Compared with SFP-DD to 2x SFP56-100G-DAC-2M7FT at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28.8mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28.8mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Volume orders can include customer references on the labels and carton list.
Generic Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.