SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

For a direct equipment connection requiring Generic SFP112 to SFP112-100G-DAC-0.5M2FT, this page supplies the 0.5m (2ft) version with SFP112 to SFP112. The cable supports 100G operation and eliminates a separate module-and-patch-cord assembly. Installation, maintenance and spare-cable identification are addressed alongside the full technical details.

OEM Part Number: SFP112 to SFP112-100G-DAC-0.5M2FTHT Part Number: SFP112 to SFP112-100G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP112 to SFP112
  • Fixed length and part number: 0.5m (2ft), SFP112 to SFP112-100G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: <0.15W
  • Minimum bend radius: 20mm

Specifications

HT Part NumberSFP112 to SFP112-100G-DAC-0.5M2FT
ManufacturerHT
Connector TypeSFP112 to SFP112
Max Data Rate100Gbps
Minimum Bend Radius20mm
Wire AWG28AWG
Cable Length0.5m (2ft)
Jacket MaterialPVC (OFNR)
Cable TypePassive Twinax
CompatibleGeneric
Power Consumption<0.15W
Power Supply3.3V
Temperature0 to 70°C (32 to 158°F)
Application100G Ethernet
Modulation Format100G-PAM4 to 100G-PAM4
ProtocolCMIS Rev5.0, SFF-8024

Signal and Lane Configuration

The listed modulation format is 100G-PAM4 to 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP112 to SFP112-100G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

SFP112 to SFP112-100G-DAC-0.5M2FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SFP112 to SFP112-100G-DAC-1M3FT at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 20mm; the stated power consumption is <0.15W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is <0.15W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

Generic Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP112 to SFP112-100G-DAC-0.5M2FT refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

You are here: Home 100BASE SFP SFP112 to SFP112-100G-DAC-0.5M2FT 100G SFP112 PAM4 Passive Copper Twinax Cable, 0.5m (2ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support