MTP-12 APC to Unterminated Pigtail Trunk Cable, Male, 144 Fibers, OS2

Our 144 Fibers (Base-12) MTP® Elite Male trunk is the fast way to move many fibers between two points. OS2 9/125μm performance, LSZH jacket, and controlled breakout geometry mean predictable loss and tidy routing in the main distribution area.
Standard lengths are 1m (3ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), 20m (66ft), 25m (82ft), 30m (98ft) and 40m (131ft). Because we are the manufacturer, any other length between or beyond these steps can be produced on request, with your choice of jacket color, labeling and packaging.
Product Highlights
- MTP® Elite Male (Pinned) to Unterminated, 144 Fibers (Base-12)
- OS2 9/125μm, G.657.A1
- Insertion loss ≤0.35dB, return loss ≥65dB
- LSZH
- Minimum bend radius 10mm
- Ten standard lengths from 1m (3ft) to 40m (131ft), custom lengths built to order
Specifications
| Part Number | 144SM-MTPA-30M-M |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MTP® Elite Male (Pinned) |
| Connector B | Unterminated |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Polish Type | APC |
| Cable Jacket | LSZH |
| Fiber Count | 144 Fibers (Base-12) |
| Glass Fiber | G.657.A1 |
| Trunk Structure | Double Jacket |
| Minimum Bend Radius | 10mm |
| Trunk Outside Diameter (OD) | 12mm |
| Breakout Outside Diameter (OD) | 2.0mm |
| Tensile Strength | 200/660N (Long/Short Term) |
| Breakout Length | 0.84m |
| Insertion Loss | ≤0.35dB |
| Return Loss | ≥65dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
Applications
This trunk is designed for permanent backbone positions: between patch panels, from the core to aggregation rows, or between buildings on a campus. The 144 Fibers (Base-12) construction concentrates the equivalent of many duplex jumpers into a single assembly, which is exactly what high density spine and leaf cabling needs. Every breakout leg is numbered, which simplifies documentation and troubleshooting.
Trunk Construction and Polarity
The trunk uses a double jacket design: a rugged outer sheath protects the whole bundle, while each breakout leg keeps its own jacket and numbering. Base-8 and Base-12 constructions are available depending on the fiber count. Polarity follows the Type shown in the table, and pulling eyes or mesh grips can be fitted for installation.
Ordering Information
Please reference 144SM-MTPA-30M-M in your enquiry. The 1m (3ft) version is the standard model; Our sales team can also advise on polarity, gender and jacket choices if your project documentation is not final yet.
Built to Your Spec
Our engineering team handles custom MPO/MTP assemblies daily. If the standard configuration does not match your link design, send us the requirement and we will build exactly what your network needs at factory-direct cost.
Quality and Testing
We do not ship untested product. Each unit is measured on calibrated equipment for optical performance and visually inspected for end face quality before packing. Batch traceability is maintained so any field issue can be tracked back to production.
Logistics
Most orders leave our facility within a few working days. Courier, air freight and sea freight are all available, and we are happy to hand goods to your nominated forwarder in China.