Custom Duplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Custom Duplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

For Tanzanian site work, correct product selection should be followed by careful transport, connector inspection and retention of the fiber records. This is the configured-to-order duplex armored platform: two fibers of OS2 9/125µm G.657.A1 glass inside a helical stainless steel tube, terminated with any combination of LC, SC, FC, ST or LSH connectors in UPC or APC polish, and jacketed in riser (OFCR), LSZH or plenum (OFNP) compound in blue, black or white. Instead of adapting a stock cord to the job, the cord is built for the job from the start. For Tanzanian site work, keep this requirement with the field checklist and the delivered product records.

Product Highlights

  • LC, SC, FC, ST or LSH connectors in any end-to-end mix
  • UPC or APC polish per end, return loss to 60/65dB class
  • Riser (OFCR), LSZH or plenum (OFNP) jacket, blue/black/white
  • Helical stainless steel armor, 120/225N tensile rating
  • Any length to order; standard range 1m to 30m stocked
  • Duplex OS2 9/125µm, built to the stated configuration

Specifications

Connector TypeLC / SC / FC / ST / LSH, any end-to-end combination
Polish TypeUPC or APC per end
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
PolarityA (Tx) to B (Rx)
Jacket ColorBlue / Black / White
Cable Outside Diameter (OD)3.0mm
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Flame RatingRiser (OFCR) / LSZH / Plenum (OFNP)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return LossUPC ≥50dB, APC ≥60dB (LC/SC/FC/ST); LSH APC ≥65dB
Operating TemperatureOFNP: 0 to 70°C; OFCR/LSZH: -20 to 70°C
Storage Temperature-40 to 70°C (-40 to 158°F)

One platform, every connector combination

LC on the transceiver, ST on the legacy panel, FC on the test set, LSH on the carrier frame: real networks mix interfaces, and this platform terminates any of them on either end of the identical armored duplex cord. Because hybrid builds arrive as one tested unit, the optical adapter pairs and their extra loss merely never enter the connection.

Choosing the jacket: OFCR, LSZH or OFNP

The jacket follows the building zone, not the other way round. Riser (OFCR) suits vertical shafts and general pathways; LSZH is specified for occupied public spaces, tunnels and transport; plenum (OFNP) is requested where the path crosses air-handling space. The armor and the optical core stay the identical across all three; thus, one diagram can mix jackets by zone without changing the optical budget.

How custom production runs

Send the connector being used mix, polish, jacket, color and length; the factory confirms the manufacturable specification, then terminates, armors and tests the patch cords to that diagram. Because every cord in the batch is measured for insertion loss and return loss against the identical limits as the stock range, a custom build carries no quality penalty.

Documentation and batch consistency

Each custom build is confirmed against a written setup before fabrication, and that setup becomes the reference for repeat orders. Because label text, leg marking and packaging can all be added to the identical diagram, the second batch arrives identical to the first. For projects rolled out in phases, this repeatability is normally worth more than any single specification line.

Color coding with black and white jackets

Beyond the standard blue, the duplex platform is jacketed in black or white on order. Black serves outdoor-adjacent and security-conscious routes where the supplied cable should not draw the eye; white disappears into finished interiors, hotel corridors and office raceway. Some administrations further use jacket color to separate networks or security zones on the identical frame. State the color with the setup and it is built into the jacket, not sleeved on afterward.

Standard lengths plus custom builds

Standard offerings are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft). Because every cord is built to order, any length in between or beyond this range may generally be produced; for long runs the factory confirms reel and packaging details with the quotation.

Factory quality control and testing

Custom patch cords are tested to the identical limits as the stock range: 0.3dB insertion loss ceiling and polish-appropriate return loss, verified per unit before packing. Because ferrule geometry is checked on every end face, and APC ends are angle-verified, a mixed-polish build performs exactly as its two polishes set out.

Purchase and Factory Support

Send the requested setup: connector types per end, polish per end, jacket rating, color and length. The factory confirms the manufacturable specification and lead time with the quotation; drawings or photos of the existing plant are welcome and speed up confirmation. For Tanzanian deliveries, the order details should include any site identification needed by the installation team.

You are here: Home 100BASE SFP Custom Duplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support