Tanzania Fiber Optics

fiber optic products manufacturing since 1995

NVIDIA/Mellanox MCP7Y50-N001 Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top InfiniBand NDR Passive Copper Breakout Cable, 1m (3ft)

NVIDIA/Mellanox MCP7Y50-N001 Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top InfiniBand NDR Passive Copper Breakout Cable, 1m (3ft)

This 1m (3ft) DAC assembly is made for installations that call for NVIDIA/Mellanox MCP7Y50-N001 at 800G. The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.

OEM Part Number: MCP7Y50-N001HT Part Number: MCP7Y50-N001

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7Y50-N001
  • 800G connectivity at 800Gbps
  • Interface configuration: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)
  • Fixed length and part number: 1m (3ft), MCP7Y50-N001
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (800G End)0.1W (200G Per End)
  • Minimum bend radius: 31mm

Specifications

HT Part NumberMCP7Y50-N001
NVIDIA/Mellanox InfiniBand CompatibleMCP7Y50-N001
ManufacturerHT
Form Factor800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)
Max Data Rate800Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length1m (3ft)
Wire AWG28AWG
Minimum Bend Radius31mm
Max. Power Consumption0.1W (800G End)0.1W (200G Per End)
Jacket MaterialPVC
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, IEEE 802.3ck, CMIS v4.0
Modulation Format8x 100G PAM4 to Quad 2x 100G PAM4

Signal and Lane Configuration

The listed modulation format is 8x 100G PAM4 to Quad 2x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), MCP7Y50-N001 is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

MCP7Y50-N001 occupies the middle of this family between MCP7Y50-N00A at 0.5m (2ft) and MCP7Y50-N01A at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Field Installation and Maintenance

Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (800G End)0.1W (200G Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (800G End)0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Quality Assurance and Packaging

The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Standard protective packing is used by default, with project documentation arranged when requested.

NVIDIA/Mellanox Compatibility and Factory Testing

A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7Y50-N001.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. MCP7Y50-N001 refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Ordering Information

Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. Quantity and any labeling instructions should be attached specifically to MCP7Y50-N001.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

You are here: Home 100BASE SFP NVIDIA/Mellanox MCP7Y50-N001 Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top InfiniBand NDR Passive Copper Breakout Cable, 1m (3ft)

Tanzania Fiber Optics

China factory:ZYT Industrial Area,Shenzhen.
Tanzania Office:Ilala,Lumumba Str,
Dar es Salaam
Email:This email address is being protected from spambots. You need JavaScript enabled to view it.

Documentation

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

support