NVIDIA/Mellanox MCP7Y50-N01A Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 4 x 200G OSFP 2 x 100G PAM4 RHS/Flat Top InfiniBand NDR Passive Copper Breakout Cable, 1.5m (5ft)

This 1.5m (5ft) DAC assembly is made for installations that call for NVIDIA/Mellanox MCP7Y50-N01A at 800G. The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) connectors and cable arrive as one complete product, ready for a direct link between suitable ports. Field-handling guidance, exact specifications and pre-packing functional checks apply to the part number shown here.
OEM Part Number: MCP7Y50-N01AHT Part Number: MCP7Y50-N01A
Product Highlights
- Compatible alternative to NVIDIA/Mellanox MCP7Y50-N01A
- 800G connectivity at 800Gbps
- Interface configuration: 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top)
- Fixed length and part number: 1.5m (5ft), MCP7Y50-N01A
- Cable construction: Passive Breakout DAC
- Conductor specification: 28AWG
- Maximum power consumption: 0.1W (800G End)0.1W (200G Per End)
- Minimum bend radius: 31mm
Specifications
| HT Part Number | MCP7Y50-N01A |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCP7Y50-N01A |
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) |
| Max Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1.5m (5ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 31mm |
| Max. Power Consumption | 0.1W (800G End)0.1W (200G Per End) |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
| Modulation Format | 8x 100G PAM4 to Quad 2x 100G PAM4 |
Signal and Lane Configuration
The listed modulation format is 8x 100G PAM4 to Quad 2x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Cable Construction and Routing
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The 800G OSFP (IHS/Finned Top) to 4x 200G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The additional half metre beyond a one-metre assembly gives MCP7Y50-N01A useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
Position Within the Length Range
MCP7Y50-N01A occupies the middle of this family between MCP7Y50-N001 at 1m (3ft) and MCP7Y50-N002 at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Field Installation and Maintenance
Inspect the route and both connectors before installation, then support the cable without pulling on either connector housing. During maintenance, release the latch properly rather than using the cable as a handle. Keep protection on unused ends, and if the assembly is removed for later use, coil it loosely and record its part number so the same length can be returned to service. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (800G End)0.1W (200G Per End); the jacket material is PVC.
Power and Thermal Planning
The rated power consumption is 0.1W (800G End)0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Quality Assurance and Packaging
The cable and both connectors are inspected before a functional link test. Connector protection and bend-safe packing reduce handling damage during transport and storage. Customer or site labels can be added for field inventories, with different lengths separated to simplify issue and return of spare assemblies. Volume orders can include customer references on the labels and carton list.
NVIDIA/Mellanox Compatibility and Factory Testing
A field-ready cable needs both correct identification and a stable operating link. Our pre-packing check therefore includes the connectors, host recognition and link behavior. For equipment with uncertain revision history, providing the host model and software release helps identify compatibility requirements before the assembly reaches the installation site. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original NVIDIA/Mellanox cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7Y50-N01A.
What details assist a compatibility review?
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
How should an unused assembly be stored?
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Can different brands be connected with the same assembly?
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Ordering Information
Request the cable by its exact part number and length, and state the equipment model if compatibility confirmation is needed. Site orders can list quantities by rack or installation team. Any requested label should retain the part number so a removed or spare cable can still be identified accurately. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.